SM303 TE Cooled Back-Thinned CCD Spectrometer
SM303: The Choice for High Speed Data Acquisition Applications
- Scientific-grade high performance
- Extremely low dark noise and stray light
- Wide dynamic range and high signal to noise ratio
- High UV Quantum efficiency
- Flexible optical input direct to slit or via fiber
- Design from the ground up for a wide range of applications
- High speed data acquisition
- Standard design allows up to 200 - 1050nm range
- New upgrades with auto shutter for dark condition
Spectral Products is offering the new SM303 TE cooled back-thinned 1024 pixel array CCD spectrometer. The SM303 is ideal for UV/VIS/NIR spectrometry that requires very high signal to noise ratio and/or high dynamic range, like fluorescence, Rama, LED property testing applications. The back-thinned CCD has excellent sensitivity in UV and allows deep UV application. Well designed housing allows up to a 850nm measurement window from 200nm to 1050nm (smaller measurement window sizes increase spectral resolution and light sensitivity) with very low stray light. The TE cooled detecor also help to measure very low light signals by reducing the noise level in long integration times. Thanks to the hidynamic range and the low noise, the SM303 is also ideal for radiometric measurement applications. Standard interface to the SM303-Si is a USB 1.1/2.0 compatible interface with 16-bit. Software support includes a SDK and DLLs for dedicated applications development and our SM32Pro Windows-based spectral acquisition and analysis software. The new upgraded SM303 provides the auto-shutter function to make dark conditions automatically. Users don't need to block any input light for setting 0% transmission (dark scan).
Software
- SM32Pro - Windows (32-bit/64-bit) based software for data acquisition and analysis
- Transmission, reflectance, and absorbance measurements
- Data export, zoom in and out, spectrum overlays, and many more features
- Color analysis tools included
- Signal average and integration time control
- DLL libraries available for easy user software development
- VC++ / VB / LabView / Matlab examples available
Model
SM 303
Detector
Hamamatsu S7031-1006 Back-Thinned CCD
Pixel: 1024 x 58
Sensing Pixel size: 24µm 24µm
Sensitivity: ~ 0.065 counts/e-
Well depth: 300Ke- (vertical) 600Ke- (horizontal)
Quantum efficiency: > 90% @650nm, 65% @250nm
Cooling: One stage TE-cooled (-10°C)Spectral Resolution
0.15 to 10nm depending on the slit and grating choices
Spectral Range
200 - 1100nm
Spectrograph f#
3.3
Fiber Coupler
SMA 905 or FC standard
Stray Light
< 0.05% avg
Dark Noise RMS
< 2 RMS counts in 16-bit @35ms integration time
Signal to Noise Ratio
> 1000 : 1
min. Integration Time
7ms
Trigger mode
Free Run mode
Software Trigger mode
External Trigger mode (9-pin connector)
TTL Edge Trigger input/digital output for monitoringOrders Sorting Filter
Longpass filter or linear variable filter installed per wavelength coverage
Computer Interface
USB 1.1 / 2.0 16-bit (0 - 65535), support up to 8-multi-channel configuration
Software
Windows XP/VISTA/Win7, 8.1, 10 (32/64bit)
SM32Pro & SM32Pro MX (free with spectrometer)Includes DLL libraries and SDKs for easy custom application development
Dimensions (inches)
9.13H x 5.12W x 3.56D inches
Weight
7lbs
Slit Options
10, 25, 50, 100, 200, and 400µm
TE Cooling Temperature
-10°C
商品属性 [波长范围] 200 - 1100nm [光学分辨率] 0.15 to 10nm