WinCamD-QD – Quantum Dot SWIR Beam Profiler
Quantum Dot SWIR Beam Profiler,GigE/USB 3.0
Features
Quantum dot sensor, optimized for 1550 or 2000 nm
Covers wavelengths 400 to 1700 nm or 350 to 2000 nm
Multiple active area options, to 1920 x 1080
15 µm pixels
14-bit ADC
Global shutter; supports pulsed and CW beams
>2100:1 dynamic range
In-firmware NUC
Parallel capture on multiple cameras
M² measurements
GigE or USB 3.0 with 3 m screw locking cable
GigE Vision/USB3 Vision support
Applications
1550 nm / 2000 nm laser profiling
Field servicing of 1550 nm / 2000 nm lasers and laser-based systems
Optical assembly & instrument alignment
Beam wander & logging
M² measurement with available M2DU stage
PLEASE NOTE:
This product requires 64-bit Windows 10. This product has a 1-year warranty.
Specification
Detail
Sensor
Colloidal Quantum Dot (CQD) on CMOS ROIC
Wavelength
S-WCD-QD-1550 series: VIS-SWIR 400-1700 nm
S-WCD-QD-2000 series: VIS-eSWIR 350-2000 nmPixel Count, H x V
S-WCD-QD-1550/2000: 640x512
S-WCD-QD-1550/2000-L: 1280x1024
S-WCD-QD-1550/2000-XL: 1920x1080Image Area
S-WCD-QD-1550/2000: 9.5x7.68 mm
S-WCD-QD-1550/2000-L: 19.2x15.36 mm
S-WCD-QD-1550/2000-XL: 28.8x16.2 mmPixel Dimension
15 x 15 µm
Min. Beam (10 pixels)
~150 µm
Shutter Type
Global
Max. Full Frame Rate
S-WCD-QD-1550/2000: 25 fps
S-WCD-QD-1550/2000-L: 25 fps
S-WCD-QD-1550/2000-XL: <25 fpsSignal to RMS Noise
≥2100:1
Opt./Elec. dB
33/66
ADC
14-bit
Measurable Sources
CW beams, pulsed sources with external synch
Measured Beam Powers
TBA
Manual Beam Attenuation
Includes ND-1, ND-2, and ND-4 C-mount ND filters
Displayed Profiles
2-D & 3-D plots
10, 16, 256 or max colors or gray. Contoured display at 10 and 16 color.Measured & Displayed Profile Parameters
Raw and smoothed profiles
[Triangular running average filter up to 10% FWHM]Beam Diameter
Diameter at two user set Clip levels
Gaussian & Second Moment beam diameters
Equivalent diameter above a user defined Clip level
Equivalent Slit and Knife Edge diametersBeam Fits
Gaussian & Top Hat profile fit & % fit
Equivalent Slit profileBeam Ellipticity
Major, Minor & Mean diameters. Auto-orientation of axes.
Centroid Position
Relative and absolute
Intensity Weighted Centroid and Geometric Center
Beam Wander Display and StatisticsMeasurement Accuracy
5 µm processing resolution for interpolated diameters
Absolute accuracy is beam profile dependent - ~10 µm accuracy is frequently achievable
Centroid accuracy is also beam dependent. It can be as good as ±10 µm since it is arithmetically derived from all pixels above the centroid clip level.Processing Options
Image & profile Averaging, 1, 5, 10, 20, Continuous.
Background Capture and Subtraction.
User set rectangular Capture Block for capture
User set or Auto ellipse Inclusion region with beam tracking for processing
*.ojf files save all WinCamD custom settings for particular test configurationsPass/Fail display
On-screen selectable Pass/Fail colors. Ideal for QA & Production.
Log data and statistics
Min., Max., Mean, Standard Deviation, to 4096 samples
Relative Power Measurement
Rolling histogram based on user's initial input. Units of mW, µJ, dBm, % or user choice (relative to a reference measurement input)
Fluence
Fluence, within user defined area
Certification
RoHS, WEEE, CE
Multiple Cameras
Up to 4 cameras, parallel capture.
1 to 8 cameras, serial capture.Camera Dimensions‚ Width x Height x Depth
61 x 61 x 99 mm
Optical depth from housing/filter to sensor ±0.2 mm
17.5 mm
Mounting
TBA
Weight
407 g (14.35 oz)
商品属性 [波长] 400-1700 nm [光束尺寸] ~150 µm [传感器] Colloidal Quantum Dot (CQD) on CMOS ROIC [像素大小] 15 x 15 µm [图像面积] 9.5x7.68 mm/19.2x15.36 mm/28.8x16.2 mm