FUSED COUPLER C OR L BAND
Fused Fiber Coupler
The fused coupler, C or L band enables the accurate splitting and monitoring of optical signals in single-mode fiber.
Gooch & Housego proprietary manufacturing technology provides uniquely low excess loss and wavelength dependence, along with low polarization and temperature dependence for both signal and tap ports.
These high performance parts are available in a wide variety of tap ratios, wavelength ranges, housings and connector options. They can therefore be readily specified in a wide variety of applications. Enabling rapid design cycles and new project builds.
Reliability is assured through qualification to Telcordia GR-1221, with a field proven FIT rate of <1.
Key Features
• Ultra-low, typically <0.05 dB excess loss
• Low wavelength dependence
• Any coupling ratio available
• High power handling
• Proven reliability
• <1 FITs
Applications
• Signal monitoring in C or L band EDFA
• Also available at 1310 nm and 1480 nm
• Network monitoring
• Network expansion
•Fixed attenuation
Compliance
• Telcodia GR-1221
Optical Specifications
Coupling
Ratio
Grade
Signal Path
Tap Path
Insertion
Loss1,2 (dB)
WDL3
(dB)
PDL4
(dB)
TDL5
(dB)
Insertion
Loss1,2 (dB)
WDL3
(dB)
PDL4
(dB)
TDL5
(dB)
Example7
Min
Max
Max
Max
Max
Min
Max
Max
Max
Max
1%
P
0.15
0.03
0.03
0.02
18.4
21.2
0.25
0.20
0.20
1%
A
0.18
0.05
0.05
0.02
17.6
22.4
0.35
0.25
0.20
2%
P
0.18
0.03
0.03
0.02
16.0
17.8
0.22
0.15
0.15
2%
A
0.20
0.05
0.05
0.02
15.2
18.2
0.30
0.20
0.15
3%
P
0.23
0.03
0.03
0.04
14.3
16.0
0.18
0.14
0.15
3%
A
0.28
0.05
0.05
0.04
13.8
17.0
0.26
0.20
0.15
5%
P
0.32
0.03
0.03
0.08
12.2
13.9
0.15
0.12
0.15
5%
A
0.40
0.05
0.05
0.08
11.9
14.4
0.20
0.20
0.15
10%
P
0.60
0.05
0.04
0.08
9.6
10.8
0.13
0.10
0.13
10%
A
0.70
0.06
0.06
0.08
9.2
11.2
0.18
0.15
0.13
50%
P
2.80
3.206
0.10
0.08
0.10
2.8
3.2
0.10
0.08
0.10
50%
A
2.70
3.40
0.15
0.10
0.10
2.7
3.4
0.15
0.10
0.10
1 Insertion loss over operating wavelength range (not including PDL, TDL or any connector losses).
2 In 2x2 couplers insertion loss is not specified for launch through the second input port, P4 (coloured blue).
3 Change in insertion loss over the operating wavelength range.
4 Change in insertion loss over all input polarization states at band center wavelength.
5 Change in insertion loss from -5 – +75ºC.
6 Housing option 2 (miniature) insertion loss 2.8/3.30 dB.
7 Any coupling ratio available – contact G&H for specification of coupling ratios not listed.
Parameter
Specification
Operating wavelength range1
C Band
1528-1563 nm
L Band
1570-1605 nm
1310 Band
1295-1325 nm
1480 Band
1465-1495 nm
Return loss/directivity2
55 dB
Pigtail tensile load
5 N
Optical power handling4,5
4 W
Operating/storage temperature range3
-40 - +75°C / -40 - +85°C
Environmental qualification
Telcordia GR 1221
1 For wavelengths within ±5 nm of the specified range performance will be maintained for signal path insertion loss, PDL, TDL, directivity and return loss. The only parameters to increase will be tap insertion loss and WDL. Maximum values of increase for both parameters are 0.1 dB for 1% tap, 0.07 dB for 2-9%, 0.05 dB for 10–50%.
2 Return loss is the ratio of power launched to power reflected for port P1. Directivity for the 2x2 component is the ratio of power launched to P1 to the power reflected to P4.
3 For connectorized component, operating temperature range is –5 – +75°C.
4 For operation at powers of greater than 4 W the component housing and fiber must be adequately heat-sunk (for additional information contact G&H sales). Components intended for high power operation are only available in the 2x2 configuration. Component performance and reliability under high power must be determined within the customer system.
5 The performance and reliability of optical connectors is not guaranteed for optical powers of greater than 1 W.
Housing Option
Housing Code
Description
Dimensions (mm)
Pigtail
2
Miniature
3.0
(∅) x
45 (L)
Primary-coated fiber
3
Regular
3.0
(∅) x
50 (L)
Primary-coated fiber
4
Semi-ruggedized slim
3.0
(∅) x
60 (L)
∅ 0.9 mm loose-tube
5
Semi-ruggedized
5.0
(∅) x
75 (L)
∅ 0.9 mm loose-tube
6
Fully-ruggedized
80 (L) x 10 (W) x 8 (H)
∅ 3.0 mm fan-out sleeving
7
High power
5 (W) x 5
(H) x 85 (L max)
Primary-coated fiber
C
Regular high power
3.0
(∅) x
50 (L)
Primary-coated fiber
Configuration
Order code
Order codes are comprised of a standard device prefix (e.g. FFC) followed by code letters or numbers, which correspond to available options.
Sample: FFC-CK31PB110 (Fused fiber coupler, C band, 50% coupling ratio, regular housing, 1x2 port configuration, P grade, coming SMF-28, 1 m pigtail length, no connectors).
1 Not available for housing option 6.
2 Minimum pigtail length. Further pigtail lengths available on request. Where connectorized, pigtail length is to connector end face.
3 Insertion loss in specification table does not include connector losses.
4 Any coupling ratio available – contact G&H for specification and ordering codes of coupling ratios not listed.
5 Connectors may be fitted to housing types 4, 5 and 6. For connectorization of other housing types please contact the sales office.
6 7 & C not available as 1x2 port configuration.
商品属性 [波长] C,L band