BGP-USB-L11059
SP90320
Comes with universal power supply, 5 meter USB A-B cable and 3 ND filters (1.0, 2.0 & 3.0 optimized for use in the region of 400-700nm; ND 3.0 filter is installed in the input aperture of the camera)
BeamGage Training DVD
L11059 Beam Profiling Camera
The L11059 camera accurately captures and analyzes wavelengths from 190nm - 1100nm. It is our largest active area at a 35mm format, has a wide dynamic range, and unparalleled signal to noise ratio, making it ideal for beam profiling of very large beams.
3ֺֺ5mm x 24mm imager format
Hֺֺighest resolution
Pֺֺrogrammable high speed electronic shutter
5ֺֺ9bB true dynamic resolution
Item
Specification
Model
L11059
Application
35mm format
Spectral Response
190 - 1100nm (2)
Active Area
35mm x 24mm
Pixel spacing
9.0µm x 9.0µm
Number of effective pixels
4008 x 2672
Minimum system dynamic range
59 dB
Linearity with Power
±1%
Accuracy of beam width
±2%
Frame rates in 12 bit mode (4)
3.1 fps at full resolution
Shutter duration
10µs to multiple frame
Gain control
0.8 dB to 56 dB
Trigger
Supports both trigger & strobe out
Photodiode trigger
Si response: SP90408
Saturation intensity (1)
0.15µW/cm2
Lowest measurable signal (1)
0.17nW/cm2
Damage threshold
0.15mW/cm2
Dimensions
83 mm x 76 mm x 128 mm
CCD recess
18.8mm
Image quality at 1064nm
Pulsed with trigger sync - excellent
Pulsed with video trigger - good
CW - good
Operation mode
Quad Tap interline transfer CCD
Software supported
BeamGage PRO
PC interface
USB 2.0
OS Supported
Windows 7 (64) and Windows 10
Notes:
(1) Camera set to full resolution at maximum frame rate and exposure times, running CW at 632.8nm wavelength. Camera set to minimum useful
gain for saturation test and maximum useful gain for lowest signal test.
(2) Camera may be useable for wavelengths below 350nm but sensitivity is low and detector deterioration may occur. Therefore UV image
converter is recommended. Although our silicon cameras have shown response out to 1320nm it can cause significant blooming which could
lead to significant errors of beam width measurement. We would suggest our XC130 InGaAs camera for these wavelengths to give the best measurements.
(3) This is the damage threshold of the filter glass of the filters. Assuming all filters mounted with ND1 (red housing) filter in the front. Distortion of the beam may occur with average power densities as low as 5W/cm2.
(4) Highly dependent on PC processor and graphics adapter performance.
Drawings
Ordering
BGP-USB-L11059
SP90320
Comes with universal power supply, 5 meter USB A-B cable and 3 ND filters (1.0, 2.0 & 3.0 optimized for use in the region of 400-700nm; ND 3.0 filter is installed in the input aperture of the camera)
BeamGage Training DVD
SP90429
How to become a great user of the world’s most powerful laser beam analysis software
商品属性 [波长] 190-1100nm [光束尺寸] 90μm - 23.8mm [兼容的光源] CW, Pulsed [传感器] Silicon CCD