iDus 416 CCD
Andor’s new iDus 416 platform boasts a unique combination of very low dark noise and very high QE, offering unrivalled sensitivity in the near-infrared. This makes it the ideal detector for NIR Raman and Photoluminescence, reducing greatly acquisition times and removing the need for inconvenient LN2 cooling.
Low dark current
Peak QE up to 95%
30 mm wide sensor
TE cooling down to -95oC
15 μm pixels
Overview
The unique 2000 x 256, 15 μm pixel array allows extended, broadband and high resolution spectral acquisition, while the fringe suppression technology virtually eliminates the optical etalonning at the higher wavelengths.
With its compact form factor and USB 2.0 connectivity, the iDus 416 can be seamlessly integrated to Shamrock USB 2.0 spectrographs and controlled from a laptop. Andor’s UltraVac™ technology carries a unique track record when it comes to performance and reliability, maintaining superb performance year after year for both Research users and industrial integrators.
Specifications
Key Specifications Model Number
DV416A-LDC-DD
DU416A-LDC-DD
Sensor Options
LDC-DD: Back-Illuminated CCD, Deep-Depletion with anti-fringing, low dark current
Active Pixels
2000 x 256
Pixel Size
15 x 15 μm
Image Area
30 x 3.8 mm with 100% fill factor
Minimum Temperatures Air Cooled
Coolant chiller, coolant @ 16°C , 0.75l/min
Coolant chiller, coolant @ 10ºC, 0.75l/min
-55ºC
-65ºC
-70ºC
-80ºC
-90ºC
-95ºC
Max Spectra per Second
30 (Full Vertical Binning)
System Window Type
Single UV-grade fused silica window, 1° wedge, AR coated on both sides optimized at 900 nm
Blemish specifications
Grade 1 as per sensor manufacturer definition
Features and Benefits
Features Benefits Low dark current
10x better than Back-Illuminated Deep-Depletion NIMO sensors, best SNR in the NIR.
Peak QE up to 95%
Best detection capability in the NIR.
15 μm pixels
Ideal for high resolution spectroscopy.
30 mm wide sensor
Superior simultaneous band-pass capture
Fringe suppression technology as standard
Optical etalonning virtually eliminated.
TE cooling down to -95°C
Critical for elimination of dark current detection limit - no inconvenience associated with LN2
Ultravac™
Critical for sustained vacuum integrity and to maintain unequalled cooling and QE performance year after year.
USB 2.0 connection
Ideal for laptop operation.
Compact and rugged platform
Ideal for OEM integration & laboratory setups.
Solis software for Spectroscopy
Comprehensive, user-friendly interface for simultaneous detector & spectrograph control
Software Development Kit (SDK)
Ease of control integration into complex setups: Matlab, Labview, Visual Basic or C/C++
Graphs
Graphs and Drawings
QE Curve - 25°C
QE Curve - minus 95°C
Darkcurrent
Dimensions - Front
Dimensions - Side
Dimensions - Rear Connector Panel
商品属性 [Active pixels ] 2000 x 256 [Pixel Size] 15 x 15 μm [Image area] 30 x 3.8 mm with 100% fill factor