X-ray Sources
Moxtek® MAGPRO X-ray sources are designed for portable and benchtop XRF instruments. Additionally, The focal spot size is ideal for X-ray imaging applications.
Applications
Materials Characterization and Identification
XRF
• Elemental composition
XRD
• Powder diffraction
• Residual stress
Imaging
• Medical R&D, small animal imaging
• Security
• Radiographic inspection
Notes
• Operating Temperature: Moxtek recommends a warm up period of 10 minutes before running below 0°C
• *Radiation Leakage: Moxtek takes every precaution with radiation leakage but it is up to the end user to make sure there is adequate protection for your needs. Consult with an application engineer for your specific application.
Features
Benefits
Small, compact design
Close coupling of detector/ source
Lightweight
Portable, easy to integrate
Stable output
High Precision of measurements, low detection limits
Multiple communication protocols
Improved heavy element analysis
High x-ray output
Short sampling time
Small spot size
Possible coupling with optics, good image resolution
70kV 12W
Improved light element analysis
Wide cone angle
Energy and flux appropriate for backscatter imaging
(70kV only) Large flat field for imaging (70kV only)
Mechanical Specifications
70kV Imaging Source
70kV XRF
Tube Type:
Metal-ceramic
Metal-ceramic
Operating Temperature:
-10 to +50° C
-10 to +50° C
Storage Temperature:
-20 to +85° C
-20 to +85° C
Cooling:
Forced air
Forced air
Weight:
≤ 900g (typical)
900g (typical)
Available Targets:
W
W, Mo
HV Polarity:
Grounded anode
Grounded anode
X-ray Tube Characteristics
High Voltage:
50 to 70kV
40 to 70kV
Beam Current:
10 to 240µA @ 50kV
10 to 300µA @ 40kV
Total Power:
12 watts (maximum)
12 watts
Focal Spot:
Typical ~-500µm FWHM
Typical ~-500µm FWHM
Window:
Beryllium 125µm or 250µm (depending on target)
Beryllium 125µm or 250µm (depending on target)
Radiation Leakage:
2mR/h at 50mm
10mR/h at 50mm
Input Power:
24 VDC, 1.1A
24 VDC, 1.1A
Standard Warranty:
1 year or 2000 operating hours
1 year or 2000 operating hours
Application
Part Number
Angle
Control Type
Target
XX
XXX
60kV
XRF (no collar)
TUB00140-XXX TUB00141-XXX TUB00142-XXX
Straight
Analog (A)
I²C (I)
SPI (S)
AG2 (Lt. Silver) RH3 (Rhodium) CR6 (Chromium) CU6 (Copper) W06 (Tungsten)
M06 (Molybdenum) W06 (Tungsten)
TUB00143-XXX TUB00144-XXX TUB00145-XXX
60 degrees
TUB00146-XXX TUB00147-XXX TUB00148-XXX
90 degrees
70kV
Not Released
Imaging (collar)
TUB00153-XX-XXX
Straight (S) 60 degrees (6)
90 degrees (9)
Analog (A)
I²C (I)
SPI (S)
W06 (Tungsten)
XRF (no collar)
TUB00154-XX-XXX
W06 (Tungsten) M06 (Molybdenum)
MAGPRO Mechanical Drawings