LSA Series: Micro motorized linear stages with Auto Detect
10 or 25 mm travel
Up to 14 mm/s speed and up to 45 N thrust
< 25 nm microstep size
Fits into the most restrictive spaces
Designed for use with an X-MCC Series stepper motor controller or any 2-phase stepper motor controller
With Auto Detect, the X-MCC controller configures its settings automatically for the connected peripheral
Mounts directly in XY (requires AB106 angle bracket for Z axis/vertical mounting)
Zaber's LSA series stages are designed to fit into the smallest spaces, without sacrificing performance or features. Small but powerful, these stages have up to 14 mm/s speed and up to 45 N thrust. With a microstep size of less than 25 nm and < 1 um repeatability, they allow for reliable ultra-fine positioning.
The LSA stages are designed to interface with our X-MCC Series universal motor controllers, offering high resolution daisy-chainable operation. Set up is easy with Auto Detect. Once connected, the X-MCC controller will automatically detect and configure the LSA. Our handy kits include free software, and all of the accessories that you will need to get the stage running right out of the box.
Part Numbering Scheme
Specification Value Alternate Unit Microstep Size (Default Resolution)
0.0238125 µm
Built-in Controller
No
Recommended Controller
X-MCC (48 V) Recommended
Repeatability
< 1 µm
< 0.000039 "
Backlash
< 5 µm
< 0.000197 "
Maximum Speed
14 mm/s
0.551 "/s
Minimum Speed
0.000015 mm/s
0.000001 "/s
Speed Resolution
0.000015 mm/s
0.000001 "/s
Encoder Type
None
Peak Thrust
45 N
10.1 lb
Maximum Continuous Thrust
25 N
5.6 lb
Guide Type
Ball bearing
Vertical Runout
< 50 µm
< 0.001968 "
Horizontal Runout
< 13 µm
< 0.000512 "
Linear Motion Per Motor Rev
0.3048 mm
0.012 "
Motor Steps Per Rev
200
Motor Type
Stepper (2 phase)
Motor Rated Current
240 mA/phase
Motor Winding Resistance
20.4 ohms/phase
Inductance
5 mH/phase
Motor Rated Power
2.35 Watts
Motor Connection
D-sub 15
Default Resolution
1/64 of a step
Motor Frame Size
NEMA 08
Mechanical Drive System
Precision lead screw
Limit or Home Sensing
Magnetic hall sensor
Axes of Motion
1
Mounting Interface
M2 and M3 threaded holes and M4 threaded centre hole
Operating Temperature Range
0 to 50 °C
Vacuum Compatible
No
RoHS Compliant
Yes
CE Compliant
Yes
Comparison - LSA Series
Part Number Travel Range Accuracy (unidirectional) Maximum Centered Load Maximum Cantilever Load LSA10A-T4A
10 mm (0.394 ")
18 µm (0.000709 ")
25 N (5.6 lb)
100 N⋅cm (141.6 oz⋅in)
LSA25A-T4A
25 mm (0.984 ")
24 µm (0.000945 ")
30 N (6.7 lb)
125 N⋅cm (177.0 oz⋅in)
Part Number Pitch Roll Yaw Weight LSA10A-T4A
0.09 ° (1.570 mrad)
0.03 ° (0.523 mrad)
0.04 ° (0.698 mrad)
0.115 kg (0.254 lb)
LSA25A-T4A
0.14 ° (2.443 mrad)
0.05 ° (0.873 mrad)
0.12 ° (2.094 mrad)
0.132 kg (0.291 lb)
Specification Charts and Notes
Thrust or torque is a function of speed. The values given above are maximums. These values cannot both be achieved simultaneously (i.e. at maximum speed, the unit will not produce maximum thrust).
商品属性 [行程] 10 or 25 mm