High Speed Swept Test System
Swept Test System
The Santec Swept Test System has been developed to streamline photonic testing, providing a complete solution where high-speed analysis, high resolution and accuracy are key. Combining one of Santec’s tunable lasers (TSL-770, TSL-710 or TSL-550) with a Santec optical power meter (MPM-210), a polarization control units (PCU-110 or PCU-100) and custom software, the complete Swept Test System optimizes WDL and PDL measurement for use in both R&D and production environments. Using real-time referencing, while simultaneously acquiring output power from the tunable laser and the transmitted optical power through the DUT, the system provides high accuracy in WDL and PDL analysis using the Muller Matrix Method. Over-sampling and rescaling algorithms are used to maximize testing throughput while maintaining measurement integrity. The santec MPM-210 power meter mainframe can be used in conjunction with the 4-channel current meter module, the MPM-213. The Swept Test System combined with the MPM-210 and MPM-213 is suitable for measuring the performance of fiber optics components using transceiverlike photodiodes (ROSA/Coherent receiver, etc.) or optical channel monitors.
Features
Real-time power referencing
1 Accurate WDL / PDL characteristics measurement
・High power repeatability < ±0.02 dB
・High PDL repeatability ±0.01 dB
2 Automatic normalization of laser source power
Rescaling algorithm utilizing the Swept Processing Unit (data acquisition unit)
1 High wavelength resolution and accuracy
2 Reduced measurement time
Multi-channel measurement is available.
Supporting Dynamic Link Library (DLLs) to develop software (VB.net, C#, C++ or LabVIEW)
1 Convenient set up of measurement parameters
2 Data analysis
Applications
Optical components and modules characterization
・Tunable Filters, Interleavers, Fiber Bragg Gratings (FBGs), Couplers, Splitters, Isolators, Switches
・WSS, Wavelength Blockers
・DWDM components Photonic material characterization Optical spectroscopy
Typical configuration
IL / PDL measurement setup with the polarization controller PCU-110 and the power meter MPM-210
IL measurement setup with the power meter MPM-210
IL measurement setup with any other power meter
Graphical user interface
Specifications
Parameter
Unit
Specifications
Notes
TSL-550
TSL-710
TSL-770
Type A
Type C
Wavelength Accuracy*1(typ.) (Absolute)
pm
±16
±4.4
±2.4
±1.6
At 10 nm/s
±18
±7.2
±4.7
±2.3
At 50 nm/s
Wavelength Accuracy (typ.) (Relative)
pm
±8
±3.1
±1.6
±1.3
At 10 nm/s
±11
±5.9
±4.2
±2.0
At 50 nm/s
Wavelength Repeatability *2
pm
±6
±1.9
±1.0
±0.6
At 10 nm/s
±8
±3.8
±2.8
±0.9
At 50 nm/s
Scan Speed
nm/s
1 to 100
1 to 200
Dynamic Range for Insertion Loss (typ.)
dB
80
Dynamic Range for PDL (typ.)
dB
0 to 5
Measurement Time for IL (typ.)
sec
3.5
4
At 50 nm/s *4, *5
Measurement Time for IL / PDL (typ.)
sec
12.5
14
At 50 nm/s *4, *5
Wavelength Resolution
pm
0.1
IL Accuracy (typ.)
dB
±0.02
0 to 30 dB Device IL
±0.1
30 to 40 dB Device IL
IL Repeatability*2, *3 (typ.)
dB
±0.02
IL Resolution
dB
0.001
PDL Accuracy (typ.)
dB
±(0.02 + 3% of PDL)
0 to 20 dB Device IL
±(0.15 + 3% of PDL) (typ.)
20 to 40 dB Device IL
PDL Repeatability*2, *3 (typ.)
dB
±0.01
PDL Resolution
dB
0.01
Communication
-
USB (USB 2.0 High Speed)
MPM-210 / SPU-100
GP-IB (IEEE488.2)
TSL Series / MPM-210 / PCU-110
Operating Temperature
ºC
15 to 35
Operating Humidity
%
< 80
non-condensing
* All specifications are quoted after 1 hour warm-up period and executing a zero calibration. All specifications applies with santec optical power meter MPM-210.
*1 Temperature within 25 ºC±5 ºC
*2 Temperature within 25 ºC±1 ºC
*3 Does not include influence of connector.
*4 The measurement condition is within wavelength resolution 5pm, wavelength range 50 nm for 1 channel.
*5 Measurement dynamic range per scan is up to 40 dB.
Ordering code
Optical Power Meter
Polarization Control Unit
PMF Patch cord (Tunable Laser (TSL)<--->PCU-110)
Please select the ordering code for PMF patch cord if purchasing the PCU-110.
Connector selection (Type / Polish): One port is same option as the PCU-110 code. (”B” and “C”)
Please select the same option as the TSL ordering code for the other port.
Fiber length 1.0m, Fiber jacket φ2.0mm
Swept Processing Unit