WinCamD-IR-BB – Broadband 2 to 16 µm MWIR/FIR Beam Profiler
Broadband 2 to 16 µm Beam Profiler,Port-powered USB 3.0
Features
Broadband 2 to 16 µm VOx microbolometer
640 x 480, 10.88 x 8.16 mm active area
17 µm pixels
Port-powered USB 3.0, 3 m screw locking cable
30 FPS update rate (7.5 FPS for export)
Integrated shutter for automated NUC
14-bit ADC
14 ms time constant – Pulsed lasers with PRR = 1 kHz appear as CW
No chopper/TEC
Parallel capture on multiple cameras
M² measurements
Applications
MWIR/FIR/CO₂ laser profiling
Field servicing of MWIR/FIR/CO₂ lasers and laser-based systems
Optical assembly & instrument alignment
Beam wander & logging
M² measurement with available M2DU stage
PLEASE NOTE:
This product requires 64-bit Windows 7, 8/8.1, or 10
Specification Detail Sensor
Vanadium oxide (VOx) microbolometer
Wavelength
Broadband MWIR/FIR: 2 to 16 µm
Pixel Count, H x V
307 kilopixels, 640 x 480
Image Area
10.88 x 8.16 mm
Pixel Dimension
17 x 17 µm
Min. Beam (10 pixels)
~170 µm
Shutter Type
Rolling
Max. Full Frame Rate
30 Hz (7.5 for export)
Signal to RMS Noise
≥1000:1
Opt./Elec. dB
30/60
ADC
14-bit
Measurable Sources
CW beams, pulsed sources (auto-trigger sync)
Measured Beam Powers
See the Approximate Saturation Power Limits graph
Manual Beam Attenuation
Provided 1" ND-1 and ND-2 reflective Germanium filters. See app note for more info.
Displayed Profiles
2-D & 3-D plots
10, 16, 256 or max colors or gray. Contoured display at 10 and 16 color.Measured & Displayed Profile Parameters
Raw and smoothed profiles
[Triangular running average filter up to 10% FWHM]Beam Diameter
Diameter at two user set Clip levels
Gaussian & Second Moment beam diameters
Equivalent diameter above a user defined Clip level
Equivalent Slit and Knife Edge diametersBeam Fits
Gaussian & Top Hat profile fit & % fit
Equivalent Slit profileBeam Ellipticity
Major, Minor & Mean diameters. Auto-orientation of axes.
Centroid Position
Relative and absolute
Intensity Weighted Centroid and Geometric Center
Beam Wander Display and StatisticsMeasurement Accuracy
5 µm processing resolution for interpolated diameters
Absolute accuracy is beam profile dependent - ~10 µm accuracy is frequently achievable
Centroid accuracy is also beam dependent. It can be as good as ±10 µm since it is arithmetically derived from all pixels above the centroid clip level.Processing Options
Image & profile Averaging, 1, 5, 10, 20, Continuous.
Background Capture and Subtraction.
User set rectangular Capture Block for capture
User set or Auto ellipse Inclusion region with beam tracking for processing
*.ojf files save all WinCamD custom settings for particular test configurationsPass/Fail display
On-screen selectable Pass/Fail colors. Ideal for QA & Production.
Log data and statistics
Min., Max., Mean, Standard Deviation, to 4096 samples
Relative Power Measurement
Rolling histogram based on user's initial input. Units of mW, µJ, dBm, % or user choice (relative to a reference measurement input)
Fluence
Fluence, within user defined area
Certification
RoHS, WEEE, CE
Multiple Cameras
Up to 4 cameras, parallel capture.
1 to 8 cameras, serial capture.Camera Dimensions‚ Width x Height x Depth
73 x 73 x 52 mm
Optical depth from housing/filter to sensor ±0.2 mm
15.5 mm
Mounting
1/4"-20 holes aligned with sensor center
Weight (Camera with 1" NDL-2 Ge filter)
422 g (14.9 oz)
PLEASE NOTE:
This product requires 64-bit Windows 7, 8/8.1, or 10
商品属性 [波长] 2 to 16 µm [光束尺寸] ~170 µm [传感器] Vanadium oxide (VOx) microbolometer [图像面积] 10.88 x 8.16 mm [像素大小] 17 x 17 µm