Optical Spectrum Analyzers - OEM Modules
Description
Optoplex’s near-infrared optical spectrum analyzer module (NIR OSA) is a high performance optical spectral engine for Process Analytical Technology (PAT) and Fiber Optic Test Equipment (FOTE) applications. Based on proprietary technologies, Optoplex’s OSA module offers much higher spectral resolution capability than those available in the market, which is demanding in today’s increasing spectroscopy applications. Other features include: compact, light-weight, low power consumption and wide wavelength coverage. Optoplex’s compact OSA engines are suitable for a variety of handheld, portable, bench-top and inline OSA/spectrometer applications.
In addition to the standard design with performance shown in next page, Optoplex has an option to integrate a very narrow filter into the standard OSA to offer a high spectral resolution design. With the high resolution design, the spectral resolution as small as 10pm can be achieved in C-band OSA. High resolution designs for other wavelength coverage are available. Please contact Optoplex for details.
Unlike other technologies employing expensive InGaAs detector array in conjunction with grating, Optoplex’s OSA uses a single InGaAs detector, which is a cost-effective solution for today’s demanding NIR spectroscopy applications.
Features and Benefits of OSA - OEM Modules
Super spectral measurement performance
Extraordinary spectral resolution
High wavelength accuracy
High power sensitivity
High power accuracy
Compact size, light weight
Fast scan speed
Software upgradeable
Cost-effective
Applications of OSA - OEM Modules
Optical spectral analyzing
Analytical spectroscopic instrumentation
Optical testing in optical communications
Optical channel/performance monitoring
Portable OSA in T&M and field test
Biomedical optics, i.e., OCT imaging
Fiber sensing
Portable OSA in defense /military applications
Standard Specifications of OSA - OEM Modules
Parameter
Unit
C-Band
C+L Band
O-Band
Full-Band
Part Number
-
OM-1C2MM353
OM-2T2MM301
OM-2O2MM302
OM-2AFOE304
Spectral Measurement
Wavelength Range
nm
1527-1567
1521-1611
1260-1360
1250-1650
Resolution Bandwidth (FWHM)
nm
0.15
0.3
0.4
3
Wavelength Accuracy
nm
0.04
0.05
0.08
1
Wavelength Repeatability1,2
pm
±10
±15
±20
±100
Wavelength Readout Resolution
pm
1
1
1
1
Wavelength Linearity1
nm
±0.01
±0.01
±0.01
±0.01
Power Measurement
Dynamic Range1
dB
+10~-55
+10~-55
+10~-55
+10~-55
Power Accuracy1
dB
±0.5
±0.5
±0.5
±1.0
Power Repeatability1,2
dB
±0.1
±0.1
±0.1
±0.1
Power Readout Resolution
dB
±0.01
±0.01
±0.01
±0.01
Power Linearity1
dB
±0.1
±0.1
±0.1
±0.1
Optical Rejection Ratio (ORR)1
@25GHz (0.2nm)
@50GHz (0.4nm)
25
@100GHz (0.8nm)
40
25
25
@200GHz (1.6nm)
50
40
40
25
General Specifications
Scanning Time
s
0.5
1
1
2
Power Consumption
W
< 2.5
Electronics Interface
-
UART
Fiber Length
m
1.0 ± 0.1
Optical Connector
-
LC/UPC
Dimension
mm
A or B
A or B
A or B
A or B
A: 100 x 70 x 10; B: 100 x 70 x 20
Operating Temperature Range
°C
0 ~ +65
Storage Temperature Range
°C
-40 ~ +85
Notes:
Operation in the Standard Resolution Mode.
15 minutes short term.