Model 34A
(The Picoprobe® Model 34A can be mounted on any micropositioner for use with any probing system.)
The PICOPROBE® MODEL 34A was engineered to meet the stringent demands of advanced high frequency circuit designers. This high impedance probe combines full DC capability, rise/fall times of 120 ps, and a nominal loading input impedance of 10 megohm shunted by 0.1 pf. Signal attenuation is 20:1 with a 50 ohm oscilloscope input. Like our other active probes, the Model 34A achieves its bandwidth using just one probe point, which greatly simplifies internal node testing without sacrificing performance. An assortment of user replaceable probe tips are available for a variety of probing needs. The Model 34A is powered by our standard Picoprobe® power supply.
Specifications
Input Capacitance
0.1pf
Input Resistance
10.0 megohm
Rise/fall time
120 ps (5V pulse)
Frequency Response
DC to 3 GHz (-3dB)
Operating Range
-7V to +10V
Linearity
0.5%
Gain Accuracy
±3%
Signal Attenuation
20 : 1
Model 34A Replacement Tips
Part Number
Tungsten Probing Wire Shaft Diameter
Point Radius
34A-4-5
5 micron
<0.1 micron
34A-4-10
10 micron
<0.1 micron
34A-4-22
22 micron
<1.0 micron
34A-4-35
35 micron
<2.0 micron
34A-4-60
60 micron
<3.0 micron
34A-4-125
125 micron
<5.0 micron
Requires the use of a Picoprobe® Power Supply. Please specify 110V or 220V when ordering.
商品属性 [Input Capacitance] 0.1pf [Input Resistance] 10.0 megohm [Rise/Fall Time] 120 ps (5V pulse) [Frequency Response] DC to 3 GHz (-3dB) [Operating Range] -7V to +10V