CCHP 3 Phase Capacitor Charging Power Supplies
The CCHP capacitor charging power supplies utilize the latest innovations in power electron- ics to deliver clean and efficient energy for pulsed power applications. A high power reso- nant inverter ensures reliable operation in harsh environments and operating conditions. The CCHP power supply can drive traditional pulse forming networks and reservoir partial discharge circuits.
The CCHP is the first commercially available 3 Ø capacitor charger designed as a low cost mod- ule for high volume OEM use. Available in 208VAC and 400VAC input voltages the power supply can be used worldwide in medical and industrial applications.
We also offer single phase versions of this power supply. Please visit our website for more information.
ADVANTAGES
• 3500j/sec. or 6000J/sec. Outputs
• Output Voltages to 4kV
• 200 to 240VAC, 3 Ø Input or
• 380 to 480VAC, 3 Ø Input
• 24V, 3amp Auxiliary Output
• Compact Reliable Design
• Universally Compatible Interface
APPLICATIONS
• Flashlamp Pumped Lasers
• Excimer Lasers
• Pulsed UV Aplications
• High Voltage Pulsed Applications
Specifications
Input
Voltage:
200 to 240 VAC, ± 10%, 3Ø 50/60Hz or
380 to 480 VAC, ± 10%, 3Ø 50/60Hz (set at factory)
Current:
CCHP-3500: 13.7A/Ø, 200V 7.2A/Ø @ 380V
CCHP-6000: 23.5A/Ø, 200V 11,6A/Ø @ 380V
Power Factor:
PF=.8
Output
Power:
CCHP-3500: 3500j/sec. avg.
CCHP-6000: 6000j/sec. avg.
Output Voltage:
Configurable from 250V to 4kV
Output Current:
2 * Poutmax/Voutmax
Polarity:
Positive or Negative (set at factory)
Efficiency:
>85% at full output
Regulation:
>0.5% @ 100Hz
Interface
Connector:
15 Pin “D” Sub Female
Voltage Program:
0 to 10 V for 0 to Max Voltage
Voltage Monitor:
0 to 10 V for 0 to Max Voltage
Inhibit/Reset
End of Charge Indication
Temperature Fault
Over Voltage Indication
Note: Interface is compatible with CCPF interface or it
can be modified to work with all popular analog inter-
face configurations
Environment
Operating Temp:
0 to 40° C
Storage:
-20 to 85°C
Humidity:
0 to 90% non-condensing
Cooling:
Forced air
Dimensions:
17.3 inch (439mm) X 16.6 (422mm) X 3.7 (94mm)
Regulatory
UL 60950 Safety
CISPR 1 Conducted and Radiated Emissions IEC 61000 Immunity