450 NM LASER (MM DIODE; MM FIBER)
描述
This is a multimode fiber coupled high power blue diode with more than 600 mW output power. 450 nm laser diode module is an excellent choice for flow cytometry, fluorescence and biomedical applications. Small footprint, stable power, low power consuption are only a few advantages of this laser.
产品规格
Parameter Minimum Value Typical Value Maximum Value Central Wavelength, nm
440
450
460
Longitudinal modes
-
multiple
-
Spectral line width FWHM, nm
-
1
2
Output power, mW
-
600 1
-
Power stability, % (RMS, 8 hrs)
-
1 2
2
Power stability, % (peak-to-peak, 8 hrs)
-
2 3
3
Noise, % (RMS, 20 Hz to 20 MHz)
-
0.4 4
1
Transversal modes
-
Multiple
-
Control interface type
-
UART/USB
-
Operation mode
-
APC (CW)
-
Modulation bandwidth, MHz
-
on request
-
Input voltage, VDC
4.8
5
5.3
External power supply requirement
-
+5 V DC, 2 A
-
Dimensions, mm
-
50 x 30 x 18 5
-
Heat-sinking requirement, °C/W
-
0.5
-
Optimum heatsink temperature, °C
15
20
30
Warm up time, mins (cold start)
0.1
0.5
1
Temperature stabilization
-
Yes
-
Overheat protection
-
Yes
-
Storage temperature, °C (non-condensing)
-10
-
50
Net weight, kg
0.1
0.12
0.14
Max. power consumption, W
5
10
20
Warranty, months (op. hrs)
-
14 (10000) 6
-
RoHS
-
Yes
-
CE compliance
-
- General Product Safety Directive (GPSD) 2001/95/EC
- (EMC) Directive 2004/108/EC-
Laser Safety Class
-
3B
-
OEM lasers are not compliant with
-
IEC60825-1:2014 (compliant using additional accessories)
-
Country of origin
-
Lithuania
-
1 The optical power can be tuned from virtually 0% to 100%. However, other specifications, such as central wavelength, power stability, noise, polarization ratio, beam shape, quality and circularity are not guaranteed at power levels other than factory preset power. Significantly worse power stability is to be expected at very low power levels, e.g. <3% from specified nominal power.
2 The long term power test is carried out at constant laser body temperature (+/-0.1 °C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.
3 The long term power test is carried out at constant laser body temperature (+/-0.1 °C) using an optical power meter with an input bandwidth of 10 Hz. The actual measurement rate has a period of about 20 seconds to 1 minute.
4 Noise level is measured with a fast photodiode connected to an oscilloscope. The overall system bandwidth is from 2 kHz to 20 MHz.
5 Excluding control interface pins and an output window/fiber assembly.
6 Whichever occurs first. The laser has an integrated operational hours counter.
Note: Product specifications are subject to change without prior notice to improve reliability, function or design or otherwise.
Typical spectrum
Typical spectrum of 0450 nm diode laser. Measured with 10 pm resolution.
Typical Near Field
Typical Far Field
Drawing
The key dimensions of a fiber-coupled MatchBox.
商品属性 [波长] 450nm [功率] 600mW [输出类型] MM DIODE; MM FIBER