CCD format:1024 x 1024 imaging pixels; 13 x 13 mm pixels; 100% fill factor Dark current:1024BR/BR_eXcelon:0.02 (typical) 0.07 (max); 1024B/BUV/B_eXcelon0.0004 (typical) 0.001 (max) 1024F:0.0002 (typical) 0.0007 (max) Imaging area:13.3 x 13.3 mm (optically centered)
CCD format:1340 x 1300 imaging pixels; 20mm x 20mm pixels; 100% fill factor Dark current:1300B/F/B_eXcelon:0.01 (typical) 0.05 (max) 1300BR:0.32 (typical) 0.65 (max) Imaging area:26.8 x 26 mm (optically centered)
CCD format:1340 x 100, 20 x 20 mm pixels with 100% fill factor Dark current:100BR/BR_eXcelon:0.03 (typical) 100B/B_eXcelon:0.0 (typical) 100F:0.0008 (typical) Imaging area:26.8 x 2.0 mm (optically centered)
CCD format:1340 x 400, 20 x 20 mm pixels with 100% fill factor Dark current:400BR/BR_eXcelon:0.03 (typical) 400B/B_eXcelon:0.001 (typical) 400F:0.0008 (typical) Imaging area:26.8 x 8.0 mm (optically centered)
CCD format:2048 x 512 imaging pixels; 13.5 x 13.5-mm pixels with 100% fill factor Dark current:0.001 (typical) Imaging area:27.6 x 6.9 mm (optically centered)
CCD format:256E:1024 x 256, 26 µm x 26 µm pixels with 100% fill factor; 256BR:1024 x 252, 26 µm x 26 µm pixels with 100% fill factor Dark current:256E:0.003 (typical) 256BR:0.3 (typical) Imaging area:256E:26 mm x 6.7 mm height 256BR:26 mm x 6.6 mm height
CCD Image Sensor:e2v CCD42-40; UV-enhanced grade 1; NIMO; back illuminated CCD format:2048 x 2048 imaging pixels; 13.5 x 13.5 μm pixels; 100% fill factor Imaging area:27.6 x 27.6 mm Dark current:0.0001
CCD Image Sensor:Princeton Instruments’ exclusive; scientific grade 1; MPP; back-illuminated; no AR coating CCD format:1340 x 100 imaging pixels; 20 x 20 mm pixels; 100% fill factor; Dark current:0.001 e-/p/sec (typical) 0.005 e-/p/sec (max) Imaging area:13.3 x 13.3 mm (optically centered)
CCD Image Sensor:Princeton Instruments’ exclusive; scientific grade 1; NIMO; back-illuminated deep depletion; no AR coating CCD format:1340 x 100 imaging pixels; 20 x 20 mm pixels; 100% fill factor; Dark current:0.03 e-/p/sec (typical) 0.065 e-/p/sec (max) Imaging area: 13.3 x 13.3 mm (optically centered)
CCD Image Sensor:Princeton Instruments exclusive; scientific grade 1; MPP; back-illuminated; no AR coating CCD format:1340 x 400 imaging pixels; 20 x 20 mm pixels; 100% fill factor; Dark current:0.001 e-/p/sec (typical) 0.005 e-/p/sec (max) Imaging area: 13.3 x 13.3 mm (optically centered)
CCD Image Sensor:Princeton Instruments exclusive; scientific grade 1; NIMO; back-illuminated deep depletion; no AR coating CCD format:1340 x 400 imaging pixels; 20 x 20 mm pixels; 100% fill factor; Dark current:0.03 e-/p/sec (typical) 0.065 e-/p/sec (max) Imaging area:13.3 x 13.3 mm (optically centered)
CCD Image Sensor:e2v CCD47-10; scientific grade 1; MPP; back-illuminated; no AR coating CCD format:1024 x 1024 imaging pixels; 13 x 13 mm pixels; 100% fill factor; Dark current:0.0004 e-/p/sec (typical) 0.001 e-/p/sec (max) Imaging area: 13.3 x 13.3 mm (optically centered)
CCD Image Sensor:e2v CCD47-10; scientific grade 1; NIMO; back-illuminated deep depletion; no AR coating CCD format:1024 x 1024 imaging pixels; 13 x 13 mm pixels; 100% fill factor; Dark current:0.02 e-/p/sec (typical) 0.07 e-/p/sec (max) Imaging area: 13.3 x 13.3 mm (optically centered)
CCD Image Sensor:e2v CCD42-10; scientific grade 1; MPP; BI-basic process (B), BI-enhanced process (BUV); no AR coating; for sensitivity between ~10 eV to 30 keV CCD format:2048 x 512 imaging pixels; 13.5 x 13.5 mm pixels; 100% fill factor; Dark current:0.001 e-/p/sec (typical) 0.006 e-/p/sec (max) Imaging area: 27.6 x 6.9 mm (optically centered)
CCD Image Sensor:e2v CCD42-40; scientific grade 1; MPP; BI-basic process (B); no AR coating; for sensitivity between ~10 eV to 30 keV CCD format:2048 x 2048 imaging pixels; 13.5 x 13.5 mm pixels; 100% fill factor; Dark current:0.002 e-/p/sec (typical) 0.006 e-/p/sec (max) Imaging area:27.6 x 27.6 mm (optically centered)
CCD Image Sensor:PI Exclusive: Scientific-grade, back-illuminated, MPP device without AR coating CCD format:1340 x 1300 imaging pixels 20 x 20 mm pixels 100% fill factor Imaging area:26.8 x 26.0 mm imaging area (optically centered) Dark current:0.05 e-/p/s(typical) 0.2e-/p/s(max)
CCD Image Sensor:Scientific-grade, back-illuminated, MPP device without AR coating CCD format:2048 x 2048 imaging pixels 13.5 x 13.5 mm pixels 100% fill factor Dark current:0.02 e-/p/s(typical) 0.1 e-/p/s(max) Imaging area:27.6 x 27.6 mm(optically centered)
CCD Image Sensor:Princeton Instruments’ proprietary CCD, back-illuminated, deep depletion, grade 1, NIMO CCD format: 1340 x 400 imaging pixels; 20 mm x 20 mm pixels; 100% fill factor Dark current:0.03 (typical) 0.065 (max) Imaging area:26.8 x 8 mm (optically centered)
CCD Image Sensor:e2v CCD47-10, back-illuminated, deep depletion, grade 1, NIMO CCD format:1024 x 1024 imaging pixels; 13 x 13 mm pixels; 100% fill factor Dark current:0.02 (typical) 0.07 (max) Imaging area:13.3 x 13.3 mm (optically centered)